summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorAnson Huang <b20788@freescale.com>2013-03-29 11:54:43 -0400
committerAnson Huang <b20788@freescale.com>2013-04-02 19:51:45 -0400
commit3c73a4c87c29cfb7af4cfdc5b457892d24b89a27 (patch)
treea6383680b9018f2b93175b89c3f02a1a6c578a92
parent7232c7ce56a9743996814783a886f5c299b5bbc2 (diff)
ENGR00256543 mx6: Update equation for thermal sensor on i.MX6DL
Use universal equation and 25C's calibration data to get thermal sensor's ratio on i.MX6DL. Signed-off-by: Anson Huang <b20788@freescale.com>
-rw-r--r--cpu/arm_cortexa8/mx6/generic.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/cpu/arm_cortexa8/mx6/generic.c b/cpu/arm_cortexa8/mx6/generic.c
index 880374d25a..253b5e036e 100644
--- a/cpu/arm_cortexa8/mx6/generic.c
+++ b/cpu/arm_cortexa8/mx6/generic.c
@@ -896,7 +896,7 @@ static inline int read_cpu_temperature(void)
* data not used, we use universal equation to get thermal
* sensor's ratio.
*/
-#if (defined(CONFIG_MX6Q) && !defined(USE_CALIBRATION))
+#if (!defined(CONFIG_MX6SL) && !defined(USE_CALIBRATION))
/*
* The universal equation for thermal sensor
* is slope = 0.4297157 - (0.0015976 * 25C fuse),